Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery

Shanghai Ecopro Environmental Engineering Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Product Highlights

  • Electrochemical Reaction Principle: Utilizes Fe oxidation and OH reduction to remove contaminants via nascent oxygen and hydrogen.
  • No Polymer Required: Fe(OH)2 and Fe(OH)3 act as excellent coagulants naturally without adding external polymers.
  • Wide Power Supply Adaptability: Supports 220V-480VAC range with no power phase sequence issues.
  • Advanced Safety Protection: Features embedded isolated voltage circuit with protection against overload, overcurrent, and phase loss.
  • Automatic Ion Detection: Automatically detects ion states in water to adjust current and voltage dynamically.
  • 1-Year Warranty Coverage: Includes comprehensive warranty and after-sales service for one full year.
  • Efficient SS Removal: High suspended solids are smoothly removed continuously near the plates without dynamic aeration.
  • European Terminal Design: Control signal terminals use detachable European style for easy re-wiring and replacement.

Product Images of Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery

Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery pictures & photos
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
  • Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
    Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery

Find Similar Products

Product Description

Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Packing & Delivery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Electrocoagulation System Introduction
Electrocoagulation system is a waste water treatment process that utilizes a metal hydroxide produced by a soluble metal anode during flocculation to remove contaminants from water. The anode material usually uses aluminum, iron and other readily available and inexpensive metals.

Electrocoagulation System Fabricate Process
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Electrocoagulation System Principle
Electrocoagulation System Features
Electrochemical reaction: Fe→Fe2++2e
Anodizing reaction: 2OH-→2[O]+2e→02+2e, The nascent oxygen [O] has the same strong oxidation function as UV, H2O2 and O3.
Cathode reduction: 2H++2e→2[H]→H2, nascent hydrogen can break bonds, COD, chromophore functional groups and multi-chain health.
The above oxidation and reduction functions occur continuously on the plates.
1. Wide adaptability of power supply: 220V-480VAC range is available, power supply controller has no power phase sequence problem
2. Safe and convenient: embedded isolated voltage circuit to ensure electrical safety; a variety of abnormal indications and protection (phase loss, overload, overcurrent, overvoltage, zero voltage, etc.); control signal terminal block uses European detachable terminals, the control loop can be re-wired when replaced.
3. Automatic control: can automatically detect the ion state in the water to adjust the current, voltage
4. Energy saving: Fe(OH)2 and Fe(OH)3 are excellent coagulants. No need polymer is a major feature of this equipment. H and OH are also produced by the natural dissociation of water. There is no need for dynamic aeration to generate agglomerated organic and inorganic substances, SS, which occurs continuously in the vicinity of the plates, and the high SS can be smoothly removed.
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery
Company Profile
Treatment of Electrocoagulation Wastewater Industrial Wastewater Treatment Machinery

About the Supplier

Watch Video
Watch Video
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.
Shanghai Ecopro Environmental Engineering Co., Ltd.

About Our Factory & Business Background

Address
3th, No. 255 Xinjinqiao Road, Shanghai, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Shanghai Port

Our Production Capability & Technical Expertise

Main Products
Sludge Dehydrator, Screw Press, Wastewater Treatment, Daf, Sludge Dewatering Machine, Static Screen, Dissloved Air Flotation, Filter Press, Sewage Treatment, Biocarrier

Our Industry Experience & Global Business Record

Export Year
2017-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period for this equipment?
We provide a 1-year warranty and after-sales service for all our electrocoagulation systems.
Does this system require polymer additives?
No, it does not. Fe(OH)2 and Fe(OH)3 produced naturally serve as excellent coagulants.
What is the power supply voltage range?
The system supports a wide range of 220V to 480VAC without phase sequence problems.
How long does it take to deliver the product?
Lead time is within 15 workdays during off-peak season and about one month during peak season.
What safety features are included?
It includes embedded isolated voltage circuits and protections for overload, overcurrent, and phase loss.
Can the system adjust to water conditions automatically?
Yes, it automatically detects ion states to adjust current and voltage for optimal performance.
What payment methods are accepted?
We accept LC, T/T, D/P, PayPal, Western Union, and Money Gram.
Where is the nearest shipping port?
The nearest port is Shanghai Port.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now